Tools · Sensaheat sizing

Heat pump calculator

Fill in the three steps and the sizing underneath moves as you go — a month-by-month heat balance for Western Australian conditions, not a rule of thumb.

1

Where the pool is

Climate and wind do most of the work.

Nearest location
How exposed is it?

Wind is the single biggest lever on a pool. A sheltered pool can need a third less heater than the same pool in the open.

2

The pool

Surface area drives the loss, volume the heat-up.

Shape
Surface
Volume
3

How you want to swim

Warmer and longer both cost; a blanket buys most of it back.

26–28 °C suits most families. Every degree above 28 adds roughly 10–15% to the bill.

When do you want to swim?

Hours in a 24-hour day the cover is on. Nights are counted first — that is how blankets actually get used.

4

Plant and power

What the heater runs on, and what that costs.

The heater only works while the filtration pump runs. Longer runs let a smaller unit do the same job.

Circulation pump

Hours the pump would run for filtration whether you heated or not. Only the hours beyond this are charged to heating.

The sizing

Request a quote
Output requiredat your run time
Heat-up from cold
Running cost
Peak heat demand

Running cost through the year

Holds temperature Needs a longer run Target not reached No heating needed Outside your season Heat it cannot deliver

What the next size up is worth

Running cost only — the purchase price moves the other way, so weigh the two together.

ModelRunning cost / seasonvs recommended Over 10 seasonsHolds target

Month by month

MonthDay air °CWithout heater °CHeat kWh/day Run neededCostResult

What sits behind the numbers

  • Climate — Bureau of Meteorology monthly normals, 1991–2020, read off the station table for each location: Perth Metro 009225, Bunbury 009965, Geraldton Airport 008051, Albany Airport 009741, Kalgoorlie-Boulder 012038, Karratha Aero 004083. Wind is the mean of the 9 am and 3 pm readings. Solar exposure is not on those tables — those figures are published regional monthly means, and the month-to-month shape is estimated rather than sourced.
  • Heat loss — evaporation (the dominant term, and the one wind drives), convection, radiation to the night sky and a small conduction allowance, less absorbed solar gain. Day and night are modelled separately rather than averaged. The Bureau measures wind at 10 m over open ground, so it is stepped down to what the water surface feels behind a fence; the exposure setting does the rest.
  • Blanket — evaporation all but stopped, convection and radiation roughly halved, and about a third of the sun reaching the water. Over a full year that comes out around a 65% cut in heating energy, which is where published figures for pool covers sit. It assumes the cover actually goes on for the hours you set, every day.
  • Heat pump — Sensaheat quote nameplate capacity at 27 °C air / 27 °C water / 80% humidity, so that is the 100% point; output falls to about 68% at 15 °C air. COP is modelled across the lift from air to water, which is why a warmer target costs more per kWh, and it is scaled to reproduce Sensaheat's own published figure of about 9 at their rating point on a half-speed compressor.
  • Sizing — the hardest month inside your chosen season, taken at a cool, dull spell rather than that month's average, plus a 5% margin so the unit is not running flat out to hold temperature. Running costs and the month-by-month table use the true averages, so they read as a normal year.
  • Heat-up — from the pool's own temperature at the start of your season, running the unit continuously, which is how a pool is actually brought up from cold. Day to day it then only needs the hours shown in the table.
  • Circulation pump — the heater only transfers heat while water is moving, so the pump is part of the running cost. Only the hours beyond the filtration you would run anyway are charged to heating; the baseline hours happen whether the pool is heated or not. On an older single-speed pump those extra hours can cost as much as the heater itself, which is the strongest argument for a variable-speed pump alongside a heater.
  • What is estimated — the climate normals and the heat pump rating conditions are sourced. The cool-spell allowance, the wind step-down, the blanket factors and the part-load efficiency gain are engineering assumptions, chosen to be conservative but not measured on your pool. Treat the result as a starting point for a conversation, not a specification.

Indicative only. Real pools have shade, spa spillovers, water features and leaks. Confirm the final selection with your AGent rep before ordering, and check the electrical supply at the equipment pad — the larger units are three phase.

Sensaheat is stocked in Perth. ES, PiX and TDX series, 9 kW to 40 kW, on the next run. Blankets, rollers and the balance chemistry to go with them.