Field guide · Water balance

White crust, rough pebblecrete, a scaled cell: is the water over-saturated?

A white crust, rough pebblecrete and a chlorinator that won't hold output can share one cause: water carrying more calcium than it can hold. Three checks tell you whether it's scale or etching, how far out the water is, and where the calcium is coming from.

The short answer

Scale forms when calcium hardness, pH or total alkalinity is too high. Test all three plus temperature and run the saturation index. Above +0.5, the water is scale-forming. Bring pH and alkalinity down with acid. To bring calcium down, partly drain and refill with lower-calcium water. That's the only practical way. In Perth, test the fill water first: scheme water hardness varies a lot by locality.

The three checks, in order

You need a test kit that reads pH, total alkalinity and calcium hardness, and a thermometer, or bring a water sample in for a LaMotte Spin Touch analysis.

1

Scale or etching?

Look at the surface, the fittings and the salt cell.

2

Run the LSI

Shows how far out of balance the water is, and in which direction.

3

Where's the calcium from?

Check the fill water, the top-ups and the chlorine the pool is on.

1Scale or etching?

  • Scale is a hard, rough deposit on surfaces, fittings and pipes.
  • On a salt chlorinator it shows as white scale on the electrodes, especially in high-calcium water, and cuts the cell's output. See salt chlorinator low output.
  • Hardness salts coming out of solution can make water cloudy when it is otherwise clean.
  • Etching is the opposite. Water short of calcium for its other levels (LSI below −0.5) can etch surfaces, corrode fittings and damage concrete and tile grout. Rough surface and a negative LSI? Suspect etching, not scale.
LSIWhat to expect
Above +0.5Scale-forming. Calcium deposits and scaling.
−0.5 to +0.5Acceptable range, with 0 as the ideal.
Below −0.5Aggressive. Corrosion or etching.

2Run the LSI

LSI = pH + TF + AF + CF − 12.1, with the temperature, alkalinity and calcium factors from a table. Our LSI calculator does the lookups for you. Aim for 0; keep it between −0.5 and +0.5.

What pushes it up: higher pH, alkalinity and temperature (temperature matters least). High alkalinity keeps pushing pH up, and calcium hypochlorite adds calcium with every dose.

Salt pools and the 12.1. The 12.1 is an average correction for total dissolved solids (TDS). Some Australian health guidelines say to switch to the industry table once TDS is above 1,500 mg/L, and almost every salt pool is well above that. In the industry table the constant rises with TDS: 12.1 below 800 mg/L, up to 12.4 for 2,900–5,500 mg/L and 12.5 above 5,500 mg/L. Using 12.1 on a salt pool overstates its LSI by roughly 0.3.

Stabiliser. Stabiliser (cyanuric acid) affects the alkalinity reading. Correct the alkalinity before you work out the LSI; see stabiliser too high.

Worked example: pH 7.4, alkalinity 100 mg/L and calcium hardness 250 mg/L at 29 °C gives an LSI of 0. The same pool at 1,000 mg/L calcium gives +0.6, and scale is likely to form.

3Fixing it

  • pH and alkalinity: hydrochloric acid (AquaGUARD Hydrochloric Acid Balance 5) or dry acid (Sodium Bisulphate) lowers pH and total alkalinity. Dose to the label.
  • Calcium: partly drain and refill with lower-calcium water. Most "calcium reducer" products chelate calcium rather than remove it: the test reading drops while the calcium stays in the water, so check what the product actually does before you rely on it. If a pool on calcium hypochlorite has excess calcium, WA Health's code suggests switching to a non-calcium chlorine.
  • Scaled cell: clean it to the cell manufacturer's instructions.

Acid safety. Dilute acid into water, never water into acid. Keep acid, scale removers and cell cleaners away from liquid chlorine: WorkSafe WA lists them as incompatible, and they can react if mixed.

Calcium hardness targets

There's no single right level; it depends on the pH and alkalinity it sits with, and published ranges differ:

SourceConcrete / tiledOther surfaces
WA Health code (public pools)50–400 mg/L for all surfaces
Manufacturers (ranges vary)200–275, 200–300 or 200–400 mg/L100–225 mg/L; fibreglass 150–250 mg/L

The WA Health range is set for public aquatic facilities. For a home pool, go by the surface maker's range, and on a salt pool the chlorinator manual.

Perth scheme water

Water Corporation annual means, 01/07/2024–30/06/2025, for selected sampling localities:

LocalityHardness (mg/L)Alkalinity (mg/L)pH
Two Rocks2281957.57
Yanchep1981637.63
Neerabup1901557.61
Mirrabooka124587.13
Mandurah50498.39
Dwellingup29116.93

Water Corporation's hardness counts calcium and magnesium together, so a pool calcium-hardness test reads lower. Two Rocks' high hardness is characteristic of its source water. Treat the table as a guide and test the fill water before you drain and refill.

Bore water. Bore-water top-ups can carry high hardness; some chlorinator manuals say pools on bore or ground water may need the cell cleaned as often as weekly. If total hardness is very high (over 800 ppm), check whether the pool is a mineral pool or filled from a bore.

When it isn't scale

  • Cloudy and dirty: look at filtration and bather load. See cloudy pool water and diagnosing dirt in a pool.
  • Cloudy but clean, balance right: suspect fine air in the water. Check coagulant dosing, the filter air release, and for air leaks on the pump's suction side.
  • Rough surface, negative LSI: suspect etching rather than scale.
  • A coloured mark, not a white deposit: see identifying pool stains.

Final step

Retest and re-run the LSI. Note the fill water's numbers on the job card, so next time you know whether the calcium is coming from the tap, the chlorine or the bore.

Based on

Checked against these and other manufacturer and trade sources, October 2026. Always follow the manufacturer's manual and the product label.

General information for pool and spa trade professionals. Every pool is different. This guide does not replace the product label, the SDS, the equipment manual or advice from a licensed tradesperson, and figures quoted from the WA Code of Practice apply to public aquatic facilities. To the extent permitted by law, AGent Sales & Services Pty Ltd accepts no liability for loss or damage arising from reliance on it. Website terms.

Water out of balance? AquaGUARD Hydrochloric Acid Balance 5 and Sodium Bisulphate go out on the next run. Call your rep or browse the range.

Hydrochloric Acid Balance 5Sodium BisulphateLSI calculator